Products
earth ground bond tester
Category:
Ground bond tester
Tel: 0595-86102626
Product Description
Earth ground tester
RS232 ground resistance tester/Ground Bond tester
Model:LW7303
Feature :
1.Small volume, light weight
2.Special linear constant current output, current output range can be up to 30 ~ 40 A
3.Simple operation, key lock function
4.Provide 5 set of memory set
5.LCD display
6.Test line impedance self zero correction, ensure accuracy of test results
7.Resistance upper and lower limit set, intelligent alarm
8.Provide remote PLC control interface
|
Parameter |
7303 |
|
|
Output current |
3.0~30.0 (A) |
|
|
Output voltage |
6V. MAX |
|
|
Output frequency |
50 or 60 Hz, ±100 ppm |
|
|
Output waveform |
Sine wave, distortion (THD) < 2%, Crest Factor (Crest Factor) = 1.3 ~ 1.5 |
|
|
Resistance setting range |
0~510(mΩ) |
0~120(mΩ) |
|
Corresponding current output |
3.0~10.0(A) |
10.0~30.0(A) |
|
Resistance resolution |
1 mΩ |
|
|
Test time (s) |
0, 0.5 – 999.9 (s) (0 = continuous) |
|
|
Judgment accuracy |
±(2% of setting +2 counts) |
|
|
Voltage set |
0.00~6.00 V |
|
|
Test mode |
four-wire measurement |
|
|
Others |
||
|
Memory |
5groups memory |
|
|
Key Lock |
To prevent any unauthorized operators arbitrarily changing the parameter |
|
|
Peripheral remote control, PLC interface |
Provide Pass, Fail, Processing remote monitoring signals and the TEST, STOP contact |
|
|
Protection |
Overload, Open circuit automatically cut off the output,light and buzzer alarm |
|
|
Display |
16 × 2 LCD display |
|
|
Dimension |
280mm(W) × 89mm(H) × 370mm(D) / 10Kg |
|